We gratefully acknowledge support from
the Simons Foundation and member institutions.
Full-text links:

Download:

Current browse context:

physics.ins-det

Change to browse by:

References & Citations

Bookmark

(what is this?)
CiteULike logo BibSonomy logo Mendeley logo del.icio.us logo Digg logo Reddit logo

Physics > Instrumentation and Detectors

Title: X-ray imaging camera using INTPIX4NA SOIPIX detector with SiTCP-XG 10GbE based high-speed readout system

Abstract: The silicon-on-insulator pixel (SOIPIX) detector is a unique monolithic-structure imaging device currently being developed by the SOIPIX group led by the High Energy Accelerator Research Organization (KEK). The detector team at KEK Photon Factory (PF) is also developing an X-ray camera using INTPIX4NA with a 14.1 $\times$ 8.7 $\mathsf{mm^2}$ sensitive area and 425,984 (832 column $\times$ 512 row matrix) pixels, with a pixel size of 17 $\times$ 17 $\mathsf{\mu m^2}$. The detector has high resolution and sensitivity for low-intensity X-rays, making it suitable for imaging in optical systems with lower X-ray intensities, such as an X-ray zooming microscope using two Fresnel zone plates (FZPs), which is also under development at PF. To enable imaging under such conditions, we developed a detector cooling system using a Peltier element to support longer exposure time (~0.5 seconds per frame). Additionally, we developed a new readout system using DAQ boards developed by PF, equipped with SiTCP-XG (network controller implemented on field-programmable gate array) that supports 10 Gbps Ethernet for high-frame-rate imaging at several hundred hertz. The new X-ray camera was tested at the PF BL-14A, BL-14B, and AR-NE1A experimental stations, and the resolution and sensitivity characteristics were confirmed. Given these confirmed characteristics, this X-ray camera is suitable for X-ray imaging using 5--20 keV X-rays under low-intensity, low-contrast conditions. These conditions are ideal for capturing soft tissues with poor contrast, objects with fine structures, and specimens vulnerable to radiation damage.
Comments: Presented at 13th International "Hiroshima" Symposium on the Development and Application of Semiconductor Tracking Detectors (HSTD13), Vancouver, Canada
Subjects: Instrumentation and Detectors (physics.ins-det)
DOI: 10.1016/j.nima.2024.169429
Cite as: arXiv:2405.08330 [physics.ins-det]
  (or arXiv:2405.08330v1 [physics.ins-det] for this version)

Submission history

From: Ryutaro Nishimura Ph. D [view email]
[v1] Tue, 14 May 2024 05:57:03 GMT (10797kb,D)

Link back to: arXiv, form interface, contact.